Liên hệ với chúng tôi để có thêm thông tin và giá tốt nhất!\
Item #
Model
Output Signal
Measurement Span (Capsule)
Wetted Parts Material 1
Process Connections (High Side)
Process Connections (Low Side)
Bolts and Nuts Material
C: 660 SST
G: 316L SST
J: B7 carbon steel
Installation
Amplifier Housing
1: Cast aluminum alloy
2: ASTM CF-8M stainless steel
3: Cast aluminum alloy with corrosion resistance properties
Electrical Connection
Integral Indicator
D: Digital indicator
E: Digital indicator with the range setting switch (push button)
N: None
Mounting Bracket
Select Approval
None
CF1: Canadian Standards Association (CSA) - Explosionproof Approval
CS1: Canadian Standards Association (CSA) - Intrinsically safe Approval
CU1: Canadian Standards Association (CSA) - Combined CF1 and CS1
FF1: FM Explosionproof Approval
FS1: FM Intrinsically safe Approval
FU1: FM Combined FF1 and FS1
KF22: ATEX - Flameproof Approval
KS21: ATEX - Intrinsically safe Approval
KU22: ATEX - Combined KF22, KS21 and ATEX Intrinsically safe Ex ic
SF2: IECEx Scheme - Flameproof Approval
SU21: IECEx Intrinsically safe and Flameproof Approval
V1U1: IECEx Scheme - Combination of KU22, FU1 and CU1
Painting - Color Change (Optional)
None
P: Painting: Color change (Amplifier cover only)
PR: Painting: Color change (Amplifier cover and terminal cover, Munsell 7.5 R4/14)
Material certificate and Cover flange, Process connector (Optional)
M11: Material Certificate - Cover flange, Process Connector
None
Oil-prohibited Use (Optional)
K1: Oil-prohibited Use - Degrease cleansing treatment
K2: Oil-prohibited Use - Degrease Cleansing Treatment with Fluorinated Oilfilled Capsule
K3: Capsule fill fluid - Fluorinated oil filled In capsule
K5: Oil-prohibited Use with dehydrating treatment - Degrease cleansing and dehydrating treatment
K6: Oil-prohibited Use with dehydrating treatment - Degrease cleansing and dehydrating treatment and fluorinated oilfilled capsule
None
Calibration Unit (Optional)
D1: P calibration (psi unit)
D3: bar calibration (bar unit)
D4: M calibration (kgf/cm2 unit)
None
Output Limits and Failure Operation (Optional)
C1: Output limits and failure operation - Failure alarm down-scale: Output status at CPU failure and hardware error is -5%, 3.2mA DC or less
C2: Output limits and failure operation - NAMUR NE43 Compliant (Failure alarm down-scale: Output status at CPU failure and hardware error is -5%, 3.2 mA DC or less)
C3: Output limits and failure operation - NAMUR NE43 Compliant (Failure alarm up-scale: Output status at CPU failure and hardware error is 110%, 21.6 mA or more)
None
Long Vent (Optional)
None
U1: Long vent - Total length: 119 mm (standard: 34 mm). Material: 316 SST
Optional Specification
A: Lightning protector
A1: Gold-plated diaphragm
CA: Data configuration at factory - Data configuration for HART communication type (Software damping, Descriptor, Message)
DG6: Advanced diagnostics
HC: 316 SST Exterior Parts (316 SST zero-adjustment screw and setscrews)
HE: Fluoro-rubber O-ring (All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F))
N4: Wired tag plate (316 SST tag plate wired onto transmitter)
PE3: European Pressure Equipment Directive (PED 97/23/EC - Category III, Module H, Type of Equipment: Pressure Accessory-Vessel, Type of Fluid: Liquid and Gas, Group of Fluid: 1 and 2; Lower limit of ambient and process temperature: -29°C
Không có nhận xét nào: