- ELR H5-IES-SC- 24DC/500AC-9 - 2900421
- Model: ELR H5-IES-SC- 24DC/500AC-9 - 2900421
- Hãng: PHOENIX CONTACT
Bộ Khởi Động Động Cơ
Ngõ vào: Điều khiển Trái / Phải
Nguồn cấp: 24 VDC
Dãi dòng điện: 1.5 A ... 9 A
Hotline: 0933.911.903 (Ms.Nhi)
Mail: thietbicongnghiepltt@gmail.com
Liên hệ với chúng tôi để có thêm thông tin và giá tốt nhất!
Bộ khởi động động cơ - đảo chiều trái phải
ELR H5-IES-SC- 24DC/500AC-9 - 2900421
Ambient conditions
Back to topAmbient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Maximum altitude ≤ 2000 m Degree of protection IP20 Device supply
Back to topRated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Type of protection Surge protection Reverse polarity protection Input data
Input name Control input right/left Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA (Input type 1) Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Type of protection Reverse polarity protection
Back to topOutput name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 9 A (AC-51) 6.5 A (AC-53a) Mains frequency 50/60 Hz Load current range 1.5 A ... 9 A (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Output data reply output
Back to topOutput name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 changeover contact Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) Overspeed tripping
Back to topOperate threshold > 45 A Response time < 2 s General
Back to topMotor starter type Reversing starter Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 14.6 W Minimum power dissipation 1.1 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data
Back to topConnection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm 5 lbf-in. ... 7 lbf-in. Connection data 2
Back to topConnection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm 5 lbf-in. ... 7 lbf-in. Insulation characteristics
Back to topRated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC Standards and Regulations
Back to topDesignation Standards/regulations Standards/regulations IEC 60947-1 IEC 60947-4-2 IEC 61508 ISO 13849 Conformance/approvals
Back to topDesignation ATEX Identification II (2) G [Ex e] [Ex d] [Ex px] II (2) D [Ex t] [Ex p] Certificate PTB 07 ATEX 3145 Designation UL approval Certificate NLDX.E228652 Designation Safety Integrity Level (SIL, IEC 61508) Identification ≤ 3 Additional text Safe shutdown Designation Safety Integrity Level (SIL, IEC 61508) Identification 2 Additional text Motor protection Designation Performance Level (ISO 13849) Identification ≤ e Additional text Safe shutdown Designation Category (ISO 13849) Identification ≤ 3 Additional text Safe shutdown UL data
Back to topSCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) FLA 6.5 A (500 V AC) Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) Category code NLDX Environmental Product Compliance
REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
- Output data load output